Product Code: 24-CE250 The Chardon Deadbreak Elbow Connector is a fully shielded and insulated termination for connecting underground cable to transformers, switch gear and other apparatus equipped

What Are You Looking For?
Product Code: 15-LPFT200 The Chardon 200A, 15kV Class Loadbreak Portable Feed Thru is designed to be installed on a parking stand, attached to a transformer or other apparatus. Two bushing insert l
Product Code: 24-CE250 The Chardon Deadbreak Elbow Connector is a fully shielded and insulated termination for connecting underground cable to transformers, switch gear and other apparatus equipped
Número de Pieza: 15/25-TB600 El Cuerpo en T CHARDON para 600/900A es un conector para sistemas de Operación Sin Carga que se puede conectar en boquillas de aparatos con frente muerto tales como t
Product Code: GLE200 The Chardon 15 kV, 25 kV & 35 kV Grounding Elbow provide a circuit between energized and non-energized sections of the distribution line. The grounding elbow can be assemb
Product Code: 35-LFE200 The Chardon 35 kV Class Fused Loadbreak Elbow Connector combines a fully-shielded and insulated loadbreak elbow with full range current-limiting fuse protection. The Chardon
Product Code: 15-SOB200 25-SOB200 35-SOB200 The Chardon Insulated Standoff Bushing, available in 15 kV, 25 kV, and 35 kV, meets the IEEE 386 standards. Made of quality peroxide-cured EPDM rubb
Product Code: 35-LIC200 The Chardon Protective Cap is an accessory product to other 35 kV, 200A products with loadbreak interfaces (bushing inserts, loadbreak junctions, feed thru inserts, etc.). I
Product Code: 15-LPFT200
The Chardon 200A, 15kV Class Loadbreak Portable Feed Thru is designed to be installed on a parking stand, attached to a transformer or other apparatus. Two bushing insert loadbreak interfaces can be mated with an elbow arrester, a loadbreak elbow, or an insulated cap. When mated with other products that meets IEEE Standard 386, the Portable Feed Thru provides a fully shielded, submersible connection for loadbreak operation.
The Chardon Portable Feed Thru meets all the requirements of IEEE Standard 386, and is fully interchangeable with competitor’s products and mating products that also meet IEEE Standard 386. The indicating ring design eliminates the guesswork of loadbreak installation, it provides feedback to determine if the elbow is properly installed.
Download resources
200A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
165A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
140A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
125A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.