200A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.

What Are You Looking For?
250A 8.3KV, Current Limiting Backup ELSP Fuse, Cooper Power System
Product Name :
Current Limiting Backup FuseCatalog Number :
CBUC08250D100Rated Voltage :
8.3KVRated Current :
250ALead Time :
4-8 weeks200A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
165A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
140A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
125A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
250A 8.3KV, Current Limiting Backup ELSP Fuse, Cooper Power System

| Current rating (A) | ELSP part numbers | Dimension B | Dimension C | Description |
| 150 | CBUC08150D100 | 11.4 (289) | 3.0 (76) | 8.3 kV 150 A |
| 165 | CBUC08165D100 | 11.4 (289) | 3.0 (76) | 8.3 kV 165 A |
| 180 | CBUC08180D100 | 11.4 (289) | 3.0 (76) | 8.3 kV 180 A |
| 250 | CBUC08250D100 | 11.4 (289) | 3.0 (76) | 8.3 kV 250 A |
| Description | Cooper PN | Hi-Tech PN | H-J PN |
| 8.3 kV Class | |||
| 30 AMP | CBUC080030C100 | HTSS132030 | 9F59CBC030 |
| 40 AMP | CBUC08040C100 | HTSS132040 | 9F59CBC040 |
| 50 AMP | CBUC08050C100 | HTSS132050 | 9F59CBC050 |
| 65 AMP | CBUC08065C100 | HTSS232065 | 9F59CBC065 |
| 80 AMP | CBUC08080C100 | HTSS232080 | 9F59CBC080 |
| 100 AMP | CBUC08100C100 | HTSS232100 | 9F59CBC100 |
| 125 AMP | CBUC08125C100 | HTSS232125 | 9F59CBC125 |
| 150 AMP | CBUC081500C100 | HTSS232150 | 9F59CBC150 |
| 165 AMP | CBUC081650C100 | HTSS232165 | 9F59CBC165 |
| 200 AMP | - | HTSS232200 | 9F59CBC200 |
200A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
165A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
140A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
125A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.