Product Code: CHBON Chardon Bayonet Fuse Holders are used to protect transformers, switchgear, and distribution systems. They are designed for use in oil filled (or approved equivalents) single pha

What Are You Looking For?
The dual element Bay-O-Net fuse protects the transformer from faults or overloads on the low-voltage side from both current and temperature aspects. The backup fuse is used to protect the transformer from internal faults (coil short-circuit faults, etc.). The standard ampere-second curve can accurately match the upper and lower fuses and circuit breakers.
Product Name :
Dual Element Bay-O-Net FuseBrand :
Cooper Power SystemVoltage :
Max 23KVStandard :
ANSI, IEEESuitable For :
4000361C99FVProduct Code: CHBON Chardon Bayonet Fuse Holders are used to protect transformers, switchgear, and distribution systems. They are designed for use in oil filled (or approved equivalents) single pha
Número de Pieza: CHIL The Chardon Isolation Link is used in series with bayonet type expulsion fuses to provide extra protection during re-fusing operations. Isolation links are not fuses and do no
Product Code: CHIL The Chardon Isolation Link is used in series with bayonet type expulsion fuses to provide extra protection during re-fusing operations. Isolation links are not fuses and do not h
25A 23KV, Bay-O-Net, dual sensing, bayonet fuse, Pad Mount Transformer, Cooper Power System
120A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
80A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
25A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
65A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
The dual element fuse is a major accessory for overcurrent protection of oil-immersed padmount transformers in power distribution systems. It is used in series with the backup fuse ) to form a "two-stage protection" solution. The dual element fuse protects the transformer from faults or overloads on the low-voltage side from both current and temperature aspects. The backup p fuse is used to protect the transformer from internal faults (coil short-circuit faults, etc.). The standard ampere-second curve can accurately match the upper and lower fuses and circuit breakers. The dual element fuse is installed in the fuse barrel, which is easy to replace, simple to install and reliable in operation. Therefore, it is widely used for high-voltage side protection of American padmount transformers.

| Current Rating | Catalog Number |
| 5 | 4038108C03B |
| 6 | 4038108C04B |
| 8 | 4038108C05B |
| 12 | 4038108C06B |
| 15 | 4038108C07B |
| 25 | 4038108C09B |
| 40 | 4038108C11B |
| 50 | 4038108C12B |
| 65 | 4038108C14B |
200A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
165A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
140A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
125A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.